A dripping relief pipe means the water heater's safety valve is opening or no longer sealing. The usual causes are pressure that climbs as the water heats, house pressure that is too high, or a worn valve. Capping the pipe is never the fix.
Do not block the outlet
Never cap, plug or restrict the relief discharge to stop the drip. The California Plumbing Code requires the discharge piping to have no valves, obstructions or means of isolation, and the manufacturer's instructions say the same in fewer words: never plug a safety relief valve. Keep clear of the outlet, because the water can be hot.
If the pipe is releasing very hot water or steam continuously, keep everyone away from the outlet, turn off the heater's gas supply valve or its circuit breaker if you can reach it safely, and call for service at once.
Why the valve opens
The temperature-and-pressure relief valve opens when the tank gets too hot or the pressure gets too high. Three conditions account for most dripping.
Thermal expansion. Water expands as it heats. If the house has a check valve, a backflow preventer or another device that will not let water push back toward the main, the extra volume has nowhere to go and the pressure rises until the relief valve lets some out. The plumbing code addresses this directly: a water system with such a device must have a properly sized expansion tank or an equivalent device.
High supply pressure. Where static pressure exceeds 80 psi, the code requires a pressure regulator. A house running above that figure, or one whose regulator has failed, can keep a relief valve weeping.
A worn valve. Mineral deposits or age can stop the valve from seating, and it drips whatever the pressure is.
What the timing suggests
- Drips only while the heater is firing or shortly after: thermal expansion.
- Drips at night or when no water has been used: high supply pressure.
- Drips all the time at the same rate: a valve that no longer seals.
- Began after a new regulator, meter or backflow device: a system that has become closed.
Look beyond the valve
Replacing the valve alone does not cure a pressure problem; the new valve will open for the same reason. A proper visit measures the static pressure, watches it while the heater runs, checks whether an expansion tank is present and still holds its air charge, and confirms the thermostat setting. An expansion tank is not permanent: its air charge can be lost over the years, and a waterlogged tank protects nothing, which is why the visit checks the charge and does not simply note that a tank is present. Do not alter the heater controls or the discharge piping yourself to experiment with the symptom.
Ask what was confirmed
A useful service report says why the valve discharged and what was done about the cause. If the recommendation is only a new valve, ask which checks ruled out expansion and supply pressure. The finished arrangement must keep the safety function intact, with a discharge pipe no smaller than the valve outlet.
Sources & further reading
The Reddit link identifies a related homeowner discussion, not verified technical advice. Manufacturer references apply to their stated products; use the instructions for your installed model.
- Water Heater T&P Valve Issues (After replacement) (Reddit topic example)
- Watts: PLT-35 expansion-tank instructions, with relief-valve warnings (Primary reference)
- California Plumbing Code: water pressure, expansion tanks and relief discharge, sections 608.2 to 608.5 (Primary reference)
This guide does not claim a professional site inspection or technical sign-off.